Keimyung Med J Search

CLOSE


Keimyung Medical Journal 2013;32(1):69-73.
Migration of Atrial Septal Defect Closure Device due to Coughign
Migration of Atrial Septal Defect Closure Device due to Coughing
Sang Woong Choi; Chang Wook Nam; Jae Pil Lee; Hyungseop Kim; Yeo Hyang Kim; Jae Hyun Kim; Kwang Sook Lee; Byung Hak Rho
Abstract
Percutaneous device closure of atrial septal defect (ASD) has emerged as an alternative to traditional surgical closure. Percutaneous device closure has advantages including less surgical morbidity; avoidance of a scar and reduced hospitalization duration compared with surgical closure and high success rate. However; some complications after procedure require immediate surgery. We report a rare complication of migration of ASD occluder into the left ventricle due to coughing.
Key Words: Cough, Heart septal defect, Septal occlude device